mine explosion-proof dust sampler CCZ20 : 10~25L/min (adjustable)
- Product overview:
+ Dust sampler is a detector for measuring the concentration of floating dust in the ambient air.
+ According to GB-20964-2007 General Technical Requirements for Dust Samplers, JJG520-2002 Dust Sampler Appraisal Regulations, Q/320581FYK001-2008 Dust Sampler Enterprise Standards
+ The ExibI level in the GB3836.4-2010 standard (essential Safety type) explosion-proof design, suitable for underground coal mines and other workplaces containing explosive gas.
+ The sampler is equipped with two types of dust pre-traps,
+ Total dust pre-trap to determine the total dust concentration;
+ Respirable dust pre-trap to determine the concentration;
+ This pre-trap can be The respirable dust and non-respirable dust that are harmful to the human body are separated.
+ Can collect both respirable and non-respirable dust samples at one time.
+ Separation efficiency reaches the "BMRC" curve standard.
+ More reliable dust separation device.
+ The instrument is also equipped with a high-performance suction pump with no pulsation air flow, large load and negative pressure capacity, automatic timing sampling, stable flow, simple operation, easy to carry and so on.
Technical parameters:
- Sampling flow rate: 10~25L/min (adjustable)
- Sampling flow error: ≤5%FS
- Sampling flow stability: Sampling flow stability within 30 minutes of the sampler ≤3.0%FS
- Load capacity: ≥200Pa
- Suction negative pressure: ≥3000Pa
- Continuous working time: ≥100min
- Working noise: ≤75dB (A)
- Flow meter accuracy: not less than 2.5.
- Sampling time error: ≤0.1%
- Average flow velocity at the sampling port: 0.5~4.0m/s
- Sampling accuracy: ≤10%
- Intrinsically safe battery pack:
+ Use Ni-H nickel-metal hydride batteries 2.3A/h, 6 cells, 4 pieces of 0.51Ω/10W current limiting resistors in series,
+ Potted with epoxy resin and placed in the battery box, rated voltage Ue : 7.2V;
+ Maximum output voltage U0: 8.4V;
+ Maximum output current I0: 3.0A.
- Dimensions: 149×202×80 (mm)
- Weight ≤1.75Kg
- Use environment temperature: 0~40℃; relative humidity: ≤95%
- Ambient atmospheric pressure: 80KPa~110KPa underground coal mines that contain gas or coal dust explosion hazard